Today:
Search Product:
Select product by model name:

>visionsystems.de/ModGate Plus 213 (6720)
 

Main Features

  • Converts between Modbus/RTU, Modbus/ASCII and Modbus/TCP over Ethernet, WLAN or Internet
  • LAN 10/100 Fast Ethernet
  • Configuration over Web interface
  • Supports Modbus Master Multiplexing
  • Supports TCP/IP, DHCP, ICMP, HTTP, DNS
  • RS232/422/485 interface selected by Software
  • Optional: Wireless network IEEE 802.11b/g/n
 

VScom ModGate+ (Plus) 213, a dual port Gateway from Modbus/RTU/ASCII to Modbus/TCP

 
 

ModGate Plus 213

Quick Link: | Main Features | More Pictures | Overview | Ethernet Interface | Serial Interface | Software | Wireless interface (option) | Power Requirements | Housing and Mounting | Environmental Data | Standards | MTBF (Mean Time Between Failures) | Warranty | Open Source Software | Ordering Information | Options | Packaging | Download |

|

  More Pictures

VScom ModGate+ (Plus) 213, a dual port Gateway from Modbus/RTU/ASCII to Modbus/TCP           
Click on the thumbnails to enlarge them …

>Back to top      

  Overview

The ModGate Plus is an easy to use Gateway between Modbus/TCP on Ethernet or WLAN, Modbus/RTU and Modbus/ASCII. ModGate Plus 213 connects two Modbus serial lines to a network running TCP/IP. It can also connect Modbus/RTU and Modbus/ASCII busses.

Hardware Characteristics

With its metal case, a wide temperature range and a flexible DC power supply, the ModGate Plus classifies as an industrial-strength device. The product line is based on a state-of-the-art RISC processor, providing a cost-effective design and low power consumption.
The serial ports can be configured to physically use RS232, RS422 or RS485, allowing the utilisation of multiple Modbus Slaves on a single serial line.

Operational Benefits

The ModGate Plus devices make Modbus operations independent of distance and OS platforms; they can be accessed and controlled via Internet and VPN connections.

The messages received on the network are sent to the destination serial line; replies from serial port are sent back across the network and vice versa. A ModGate Plus device functions automatically, whether a Modbus Master is on a serial port or on the TCP/IP network.

Modbus Master Multiplexing is implemented as an extension to the standard: Several Masters can connect to ModGate Plus using Modbus/TCP whilst slaves on serial lines may answer requests from multiple Masters.

The configuration of ModGate Plus is done via browser. The user interface is based on modern web technologies to allow for an easy navigation through the configuration options provided. Furthermore, UPnP provides a simple and standardized way to find the Gateway in the network.

ModGate Plus devices can be ordered with an embedded module for WLAN 802.11b/g/n.

  Ethernet Interface

Speed/Type

100Mbps/10Mbps Auto-detecting

Connector

RJ45 (8P8C) 8 pin

LEDs

Power, WLAN, Ready, Ethernet Link / Speed

>Back to top      

  Serial Interface

No. of Ports/Type

2 × RS232/422/485 selected by software

Connector

DB-9 male

Protection

16kV ESD surge protection

Operating Modes

  • RS232
  • RS422 full duplex              (120Ω on/off)
  • RS485 4 wire, full duplex    (120Ω on/off)
  • RS485 2 wire, half duplex   (120Ω on/off)

Configuration

Software sets operating mode and RS422/485 termination
No High/Low biasing resistors needed

Signals

  • RS232: TxD,RxD, RTS,CTS, DTR,DSR, DCD, RI, GND
  • RS422: Tx+/-, Rx+/-, GND
  • RS485 4 wire: Tx+/-, Rx+/-, GND
  • RS485 2 wire: Data+/-, GND

RS485 Data Direction control

ARTc (Automatic Receive Transmit control)

Data bits

7, 8

Stop bits

1, 2

Parity

None, Even, Odd

Baudrate

ModBus: up to 115.2 kbps
RS232: 200 bps to 921.6/1000 kbps (physical)
RS422/485: 200 bps to 3.7Mbps (physical)

LEDs

TxD/RxD for each port

>Back to top      

  Software

Installation

DIP switches set the device to DHCP or a defined fixed IP Address to be contacted via WEB Browser

Operating mode

Promiscous Mode
Messages received from the network are sent to the defined serial port, messages from the serial port are sent to the connected network host. (Circuit Switching)
Direct Mapping Mode
Received messages are scanned for their target address. This address is found in the mapping table, the message is sent to the defined connection. (Packet Switching)

Network Protocols

Modbus/TCP, TCP/IP, DHCP, ICMP, HTTP, DNS, UDP, UPnP/SSDP

Serial Protocols

Modbus/RTU and Modbus/ASCII

Modbus Master Multiplexing

An extension to the standard. Slaves on serial lines may answer requests from multiple masters. The masters connect to ModGate Plus by Modbus/TCP.

Configuration

Configuration over WEB Browser

Detection

Announces presence in the network via Universal Plug and Play (UPnP) protocol

DNS

Domain Name Server support

Firmware

Firmware update over WEB Browser

Security

Webinterface is password protected. The password can be changed in the Webinterface.

USB 2.0

for logging/debugging

>Back to top      

  Wireless interface (option)

Standards

2.4GHz Radio, supports IEEE Std. 802.11b/g/n

WLAN Modes

Access Point (AP) or Client (Station)

TX Power

802.11b:
Typ. 15.5dBm ±1.5 dBm @ 1Mbps (DSSS)
Typ. 15.5dBm ±1.5 dBm @ 11Mbps (OFDM)
802.11g:
Typ. 15.6dBm ±1.5 dBm @ 6Mbps (CCK)
Typ. 13.5dBm ±1.5 dBm @ 54Mbps (OFDM)
802.11n:
Typ. 13.4dBm ±1.5 dBm @ 6.5Mbps (OFDM)
Typ. 13.3dBm ±1.5 dBm @ 150 Mbps(OFDM)

RX Sensitivity

802.11b:
-95.6dBm @ 1Mbps, -88dBm @ 11Mbps
802.11g:
-91.3dBm @ 6Mbps, -74.2dBm @ 54 Mbps
802.11n:
-88.8dBm @ 6.5Mbps (20 MHz), -72dBm @ 72.2Mbps (20 MHz)

Transmission Rate

802.11b: 11Mbps
802.11g: 6 to 54Mbps
802.11n: 6.5 to 150Mbps

Transmission Distance

Up to 100m in open areas

Wireless security

  • WEP
  • WPA
  • WPA2
  • WPA2-Enterprise (IEEE 802.1X/RADIUS)

Antenna Connector

RP (Reverse-Polarity) SMA

>Back to top      

  Power Requirements

Input Voltage

9 - 54V DC

Power Consumption

0.25A @ 12V, 2.8W max

Connector

3-pin Terminal Block

>Back to top      

  Housing and Mounting

Case

0.8mm sheet metal

Weight

w/o box 0.25kg; w/h box 0.35kg

Dimensions

115×73×25 mm³ (W×L×H)

Packaged

150×107×48 mm³

Mounting

  • DIN-Rail (optional)
  • Wall mount (optional)

>Back to top      

  Environmental Data

Operating Temp

−20°C - 65°C

Storage Temp

−20°C – 85°C

Ambient Humidity

5-95% non condensing

>Back to top      

  Standards

Declarations

CE, FCC

EMI

  • EN 55022 Class B
  • EN 61000-3-2: Limits of harmonic current emissions
  • EN 61000-3-3: Limitation of voltage changes
  • 47 CFR FCC Part 15 Subpart B

EMS (EN 55024)

  • EN 61000-4-3: Radiated RFI
  • EN 61000-4-4: Electrical Fast Transient
  • EN 61000-4-5: Surge
  • EN 61000-4-6: Induced RFI
  • EN 61000-4-8: Power Frequency Magnetic Field
  • EN 61000-4-11: Power supply dips

ESD

EN 61000-4-2 4kV contact 8kV air for

  • Serial Ports
  • USB
  • Ethernet
  • DC Power connector

>Back to top      

  MTBF (Mean Time Between Failures)

MTBF

40.1 Years @ 25°C
13.3 Years @ 45°C

Standard

Telcordia (Bellcore) Standard; RelCalc. 5.0 BELL-7

>Back to top      

  Warranty

Warranty Period

2 years

>Back to top      

  Open Source Software

Licenses

This product uses open source software to fulfill part of its functions. Licenses for the open source software are granted under the GNU General Public License in various versions. For details about those see the information in the firmware download and visionsystems.de/opensource

>Back to top      

  Ordering Information

6720

ModGate Plus 213 (2x RS232/422/485)

>Back to top      

  Options

6031

Power adapter 110-230V AC to 12V @1A, DC, EU plug

6034

Power adapter 110-230V AC to 12V @1A, DC, US plug

6689

WLAN Kit internal
internal module 802.11b/g/n, pigtail and antenna
Purchase time option, not for later retrofitting

6692

DK-NCP DIN-Rail mounting kit (clamp on rear side)

6693

WK-NCP Wallmount kit

6698

DSK-NCP DIN-Rail side mount kit (clamp on left side)

6064

DB9F-to-TB/10 for RS422/485 free wiring option

6061

DB9F-to-RJ45 for changing from DB9 to CAT5 wiring
(Optimised for RS422/485 operating modes)

6062

RJ45-to-DB9M for changing back from CAT5 to DB9 wiring
(Required to match the DB9 pinout at USB-COM Plus Mini)

661

Serial Null-Modem adapter 9PF-9PF, change male to female

>Back to top      

  Packaging

Packing list

  • ModGate Plus 213
  • Terminal block for Power Supply

>Back to top      

Download

 
 (Manual Edition July 2019)
 (Firmware 2.2.0 (January 22, 2020))
>Back to top      

* Specifications are subject to change without notice.
* All trademarks and brands are property of their rightful owners.