Today:
Search Product:
Select product by model name:

>visionsystems.de/NetCAN Plus 110
NetCAN Plus 120 WLAN (424)
 

Main Features

  • Connects CAN-Bus via LAN to PC
  • Supports CAN 2.0A / 2.0B at 1MBit/s
  • LAN 100/10 Ethernet auto-detect
  • WLAN 802.11b/g/n (WLAN model only)
  • CANopen supported by CANFestival
  • SAE J1939 protocol supported by Vscom’s J1939 API
  • Bridge mode to tunnel 2 CAN-Busses
  • Easy-to-use DLL Library for CAN bus access
  • Remote Frame support, Listen only mode
  • OS supported: Windows, Linux, Windows CE
  • Development: C/C++, C#, VB.NET, LabVIEW, Delphi
  • Secure Remote Access by viaVPN Cloud (optional)
  • Supports Bosch Busmaster Debugging
  • 16kV ESD surge protected
  • Wide range power supply 9 - 54V
  • Extended temperature −20C - +65°C
  • DIN-Rail mountable (optional)
 

Vscom NetCAN+ (Plus) 110, a CAN Bus Gateway for Ethernet/WLAN/Internet

 
 

NetCAN Plus 110
NetCAN Plus 120 WLAN
(Net-CAN 110, Net-CAN 120 WLAN)

Quick Link: | Main Features | More Pictures | Overview | Ethernet Interface | CAN Bus | Operating Modes | Software | Installation & Configuration | Security | viaVPN Remote Access (option) | Wireless interface (WLAN model only) | Power Requirements | Housing and Mounting | Environmental Data | Standards | MTBF (Mean Time Between Failures) | Warranty | Open Source Software | Ordering Information | Options | Packaging | Download |

|

  More Pictures

Vscom NetCAN+ (Plus) 110, a CAN Bus Gateway for Ethernet/WLAN/Internet                 
Click on the thumbnails to enlarge them …

>Back to top      

  Overview

The NetCAN Plus series consists of smart Ethernet to CAN-Bus gateways, making the integration of CAN-Busses into existing Ethernet network topologies possible. Higher layer protocols, such as CANopen, can be assembled using the available development tools for complex automation control applications. Properties such as low power consumption (2W typical), an extended temperature range (−20C - +65°C), a wide power supply (9 - 54V DC) and a solid MTBF (17 Years at 45°C) make it an ideal system for industrial automation. The Wireless LAN also supports connections from PC to the NetCAN Plus without an existing Wifi network.

Operation Modes

NetCAN Plus series supports three operating modes: TCP Raw Server, CAN Bridge and Driver Mode. With the TCP Raw Server the communication is handled directly via IP address and port number. The CAN Bridge connects two CAN-Busses over an Ethernet/WLAN/VPN tunnel using two NetCAN Plus devices (read more …). The Driver Mode requires the installation of a virtual com-port driver, which makes the network fully transparent to the application.

Usage Options

NetCAN Plus provides various software tools to interface each level of the user applications:

  • The ASCII conversion protocol is handy in developing and testing any CAN-BUS configuration. Users simply connect directly via Telnet, and have a simple way to talk to the CAN controller. The device can also be used to manually transmit and receive CAN frames.
  • Applications programmed by users should use the VScan API library (DLL), which handles the communication and ASCII conversion for the CAN frames in a transparent manner. In their applications, programmers have to handle only the CAN frames and status information, without taking care of the ASCII conversion. The VScan API is supported in C/C++, C#, VB.NET, Delphi and LabVIEW. Under Linux SocketCAN can be used as alternative to VScan API. All VScom CAN devices support the standard Serial Line CAN (slcan) driver.
  • The NetCAN Plus series also supports CANFestival, an Open Source CANopen Framework. CANopen is a CAN-based higher layer protocol that is used in various application fields to unburden the developer from dealing with CAN-specific details. CANopen provides standardised communication objects for real-time data, configuration data as well as network management data.
  • The SAE J1939 protocol, resting upon the CAN hardware layer, is commonly used in the commercial vehicle area. A lot of other modern protocols are based on it, like NME200, ISOBUS, MilCAN or FMS. Vscom’s J1939 API also includes support for the so called Transport Protocol, which will bypass the limit of 8 data bytes per message. It's available on J1939-enabled devices. Supports Windows, Linux, .NET   read more …

Secure Remote Access

For the NetCAN Plus series there is a software option using the viaVPN Cloud system (www.viaVPN.com), which can be remotely accessed and monitored over the Internet. viaVPN provides secure and strongly encrypted access, without the need for any reconfiguration of existing firewalls. In case a customer's firmware/application is accessible via Ethernet or Wifi — as for example via a web interface or Telnet/SSH connection — viaVPN extends the access over internet by a protected VPN tunnel. If the CAN-Bus port is not occupied by local access, also remote operation over Internet is possible.

  Ethernet Interface

Speed/Type

100Mbps/10Mbps Auto-detecting

Connector

RJ45 (8P8C) 8 pin

LEDs

Power, WLAN, Ready, Ethernet Link / Speed

>Back to top      

  CAN Bus

No. of Ports/Type

1 × CAN Bus

Connector

DB9 male

Protection

16kV ESD surge protection

Signals

CAN_H, CAN_L, CAN_GND

Speed

CAN 2.0A / 2.0B 1Mbit/s

LED

CAN-Data, CAN-Error

>Back to top      

  Operating Modes

TCP Raw Server

Raw Data transfer over TCP/IP. Accepts multiple incoming connections.

CAN Bridge

CAN networks are connected via TCP/IP (WLAN or Ethernet). A client connects to a Server, CAN frames received on one network are repeated on the other network.

Virtual Com Mode

Driver for virtual COM port available for

  • Windows 2000, XP up to Windows 10
  • Windows Server 2000 up to 2008 R2

>Back to top      

  Software

VSCAN API

  • Unified API for control all VScom CAN-Adapters.
  • Supported OS: Windows, CE, Linux (x86, x86-64, ARM) targets.
  • Supported Dev.Env: C/C++, C#, VB.NET, Delphi and LabVIEW.

Linux OS

Supports SocketCAN (slcan driver) since kernel 2.6.38+
Also see this FAQ

CANopen

Open source CANfestival framework fully implements CANopen functionality.

SAE J1939

Automotive protocol suite supported by Vscom’s J1939 API.
Supports NME200, ISOBUS, MilCAN and FMS protocols for Windows, Linux and .NET

Monitoring Tools

Bosch BUSMASTER v3.2.0 and above

Data Coding

ASCII format

CAN Modes

Standard Mode
Normal operation on CAN bus
Listen Mode
Passive receive of CAN Frames, neither ACK bits nor Error Frames are sent
Self Reception (Echo Mode)
For testing: Transmitted Frames are also received by the adapter

>Back to top      

  Installation & Configuration

UPnP

With Network discovery enabled NetCom Plus servers announce their presence via UPnP making their IP visible.

Configuration

  • NetCom Manager to find and configure NetCANs in network
  • Driver Panels, WEB Browser, Serial Console, Telnet, SNMP

Firmware Update

via WEB Browser

Firewall

Virtual-COM mode works through firewalls

>Back to top      

  Security

Password Protection

for all available configuration options e.g. via WEB-Browser

Secure Server

create openVPN™ tunnels, for encrypted transmission of all serial and configuration data using high security SSL/TLS standards.

>Back to top      

  viaVPN Remote Access (option)

Connect via Internet

viaVPN technology provides easy and secure access to remotely installed NetCom Plus servers for their configuration or for connecting their virtual COM ports through Internet. With the viaVPN option the NetCom Plus servers are no more limited to only work inside of a local network.

Security

All communications use openVPN-tunnels encrypted by SSL/TLS and AES-256 standards.

Firewall friendly

No Reconfiguration of firewalls is required for viaVPN remote access.

>Back to top      

  Wireless interface (WLAN model only)

Standards

2.4GHz Radio, supports IEEE Std. 802.11b/g/n

WLAN Modes

Access Point (AP) or Client (Station)

TX Power

802.11b:
Typ. 15.5dBm ±1.5 dBm @ 1Mbps (DSSS)
Typ. 15.5dBm ±1.5 dBm @ 11Mbps (OFDM)
802.11g:
Typ. 15.6dBm ±1.5 dBm @ 6Mbps (CCK)
Typ. 13.5dBm ±1.5 dBm @ 54Mbps (OFDM)
802.11n:
Typ. 13.4dBm ±1.5 dBm @ 6.5Mbps (OFDM)
Typ. 13.3dBm ±1.5 dBm @ 150 Mbps(OFDM)

RX Sensitivity

802.11b:
-95.6dBm @ 1Mbps, -88dBm @ 11Mbps
802.11g:
-91.3dBm @ 6Mbps, -74.2dBm @ 54 Mbps
802.11n:
-88.8dBm @ 6.5Mbps (20 MHz), -72dBm @ 72.2Mbps (20 MHz)

Transmission Rate

802.11b: 11Mbps
802.11g: 6 to 54Mbps
802.11n: 6.5 to 150Mbps

Transmission Distance

Up to 100m in open areas

Wireless security

  • WEP
  • WPA
  • WPA2
  • WPA2-Enterprise (IEEE 802.1X/RADIUS)

Antenna Connector

RP (Reverse-Polarity) SMA

>Back to top      

  Power Requirements

Input Voltage

9 - 54V DC

Power Consumption

0.25A @ 12V, 2.7W max

Connector

3-pin Terminal Block

>Back to top      

  Housing and Mounting

Case

0.8mm sheet metal

Weight

w/o box 0.25kg; w/h box 0.40kg

Dimensions

115×73×25 mm³ (W×L×H)

Packaged

150×107×48 mm³

Mounting

  • DIN-Rail (optional)
  • Wall mount (optional)

>Back to top      

  Environmental Data

Operating Temp

−20°C - 65°C

Storage Temp

−20°C – 85°C

Ambient Humidity

5-95% non condensing

>Back to top      

  Standards

Declarations

CE, FCC

EMI

  • EN 55022 Class B
  • EN 61000-3-2: Limits of harmonic current emissions
  • EN 61000-3-3: Limitation of voltage changes
  • 47 CFR FCC Part 15 Subpart B

EMS (EN 55024)

  • EN 61000-4-3: Radiated RFI
  • EN 61000-4-4: Electrical Fast Transient
  • EN 61000-4-5: Surge
  • EN 61000-4-6: Induced RFI
  • EN 61000-4-8: Power Frequency Magnetic Field
  • EN 61000-4-11: Power supply dips

ESD

IEC 61000-4-2 4kV contact 8kV air for

  • CAN Bus Port
  • USB
  • Ethernet
  • DC Power connector

>Back to top      

  MTBF (Mean Time Between Failures)

MTBF

42.4 Years @ 25°C
13.7 Years @ 45°C

MTBF WLAN model

34.4 Years @ 25°C
12.7 Years @ 45°C

Standard

Telcordia (Bellcore) Standard; RelCalc. 5.0 BELL-7

>Back to top      

  Warranty

Warranty Period

2 years

>Back to top      

  Open Source Software

Licenses

This product uses open source software to fulfill part of its functions. Licenses for the open source software are granted under the GNU General Public License in various versions. For details about those see the information in the firmware download and visionsystems.de/opensource

>Back to top      

  Ordering Information

424

NetCAN Plus 110

429

NetCAN Plus 120 WLAN

>Back to top      

  Options

6031

Power adapter 110-230V AC to 12V @1A, DC, EU plug

6034

Power adapter 110-230V AC to 12V @1A, DC, US plug

6679

Activate option viaVPN for secure remote access over Internet

411

Purchase-time option to enable protocol J1939

6692

DK-NCP DIN-Rail mounting kit (clamp on rear side)

6693

WK-NCP Wallmount kit

662

DK 35A Plastic DIN-Rail mounting kit (use with 6693)

6064

DB9F-to-TB/10 for CAN bus free wiring option

>Back to top      

  Packaging

Packing list

  • NetCAN Plus CAN Bus Gateway
  • Terminal block for Power Supply
  • Reverse SMA Antenna (WLAN model only)

>Back to top      

Download

 
 (Firmware 3.4.8)
 (Firmware version 4.0.3 (June 28 2023), Upgrade from v3.4.8)
 (Driver Installer (version 2.0.3.0   November 2 2018))
 (Driver Installer (version 2.0.3.0   November 2 2018))
 (Virtual Com Ports (WHQL version 1.5.9.3   December 10 2007))
 (VSCAN standard API 1.10.2 for VScom CAN adapters)
 (VSCAN standard API 1.10.2 for VScom CAN adapters)
 (VSCAN standard API 1.8.0 for VScom CAN adapters)
 (Edition: April 2023)
 (Edition: May 2022)
 (VSCAN API for J1939, Feb. 14 2018)
 (Edition: October 2020)
 (Bosch BUSMASTER v3.2.2 VScom v1.0, April 2018)
 (regmodify, VS_CAN_Search, VS_CAN_TEST_SIMPLE, vscandump)
 (LabView, C#, VB.Net, Delphi, Python and more)
>Back to top      

* Specifications are subject to change without notice.
* All trademarks and brands are property of their rightful owners.
Copyright © 2005-2024, VS Vision Systems GmbH. All Rights Reserved.