Search Product:
Select product by model name:

> NetCAN Plus 110 (424)


  • Connects a PC to CAN bus via Ethernet, WLAN and Internet
  • Supports CAN 2.0A and CAN 2.0B
  • CAN High Speed up to 1 MBit/s
  • USB expansion port for WLAN
  • LAN 1000/100/10 Ethernet auto-detect
  • Remote Frame support, Listen only mode
  • CAN Bridge operation
  • Supports Windows 2000 to Server 2012, CE
  • Supports Linux (x86, x86-64, ARM)
  • Supports C/C++, C#, VB.NET, Delphi and LabVIEW
  • CANopen supported by CANFestival
  • Driver emulates serial port for easy access
  • Library (DLL) for standard access
  • ASCII conversion protocol via TCP/IP
  • Supports Bosch Busmaster Debugging
  • Optional: Wireless network IEEE 802.11b/g/n
  • Metal case

Vscom NetCAN+ (Plus) 110, a CAN Bus Gateway for Ethernet/WLAN/Internet New


VScom NetCAN Plus 110

Quick Link: | Features | More Pictures | Overview | Application | CAN | Network | Operating Modes | Special Features | Security | Driver and Software | Power and Environment | Ordering Information | Options | Packaging |


  More Pictures

Vscom NetCAN+ (Plus) 110, a CAN Bus Gateway for Ethernet/WLAN/Internet        
Click on the thumbnails to enlarge them …

>Back to top      


The VScom NetCAN+ 110 is an easy to use gateway from Ethernet to CAN-Bus, based on state of the art RISC components. It provides CAN-BUS communication over Ethernet and WLAN, and allows completely secured communication for both data transfer and configuration to the attached CAN devices.

CAN BUS is widely used in industrial applications as well as in automotive monitoring and control. The VScom NetCAN+ can be used to monitor the data traffic as well as sending control information.

NetCAN+ supports three operating modes: TCP Raw Server, CAN Bridge and Driver Mode. With TCP Raw Server the communication is handled directly via IP address and port number. The CAN Bridge connects two NetCAN+ devices to tunnel CAN data via Ethernet/WLAN. The Driver Mode requires the installation of a virtual com-port driver, which makes the network fully transparent for the application. NetCAN+ provides various software tools to interface the user application:
• The ASCII conversion protocol is useful in developing and testing any CAN-BUS configuration. Users just connect directly via Telnet, and have a simple way to talk to the CAN controller. It can also be used to manually transmit and receive CAN frames.
• Applications programmed by users should use the VScan API library (DLL), which transparently handles the ASCII conversion for the CAN frames. Programmers have to handle only the CAN frames and status information, they do not have to care more about the ASCII conversion in their applications. This API is supported in C/C++, C#, VB.NET, Delphi and LabVIEW.
• The NetCAN+ also supports CANFestival, an Open Source CANopen Framework. CANopen is a CAN-based higher layer protocol that is used in various application fields, such as medical equipment, offroad vehicles, maritime electronics, railway applications or building automation. CANopen unburdens the developer from dealing with CAN-specific details such as bit-timing and implementation-specific functions. It provides standardized communication objects for real-time data, configuration data as well as network management data.
• CANHacker, a tool for analyzing and transmitting frames on the CAN BUS, is included in the product package. This requires the Driver Mode.
• A set of Mapper DLLs simulates CAN hardware from other manufacturers. Users configure their system for those products or the NetCAN+ 110 adapter as a replacement. So existing software will use the NetCAN+ without replacing the application or modifying it.


Industrial / Factory / Laboratory automation
SCADA system
Railway applications
Maritime electronics
Wafer fabrication system
Automotive test equipment
Medical equipment
off-road vehicles



CAN High Speed (20kbit/s up to 1Mbit/s) for transmit/receive




DSub9 male


CAN activity (Data), CAN Error

>Back to top      


Ethernet interface

Auto-detecting 1000BaseT/100BaseTx/10BaseT (GigaLAN)
Connector 8P8C (RJ45)

Wireless interface

Optional via internal module or external USB stick
IEEE 802.11b/g/n operation in Access Point or Client Mode

Connector type

SMA-Reverse for WLAN antenna


TCP/IP, Telnet, DHCP, ICMP, HTTP, SNMP v1/2c/3, DNS

USB port

USB 2.0 High Speed, for WLAN


Ethernet Link+Speed, WLAN

>Back to top      

  Operating Modes

TCP Raw Server

Raw Data transfer over TCP/IP. Accepts multiple incoming connections.

CAN Bridge

CAN networks are connected via TCP/IP (WLAN or Ethernet). A client connects to a Server, CAN frames received on one network are repeated on the other network.

Driver Mode

VScom Driver for

  • Windows 2000, XP up to Windows 8.1
  • Windows Server 2000 up to 2008 R2
Driver Mode creates a virtual Com port.

>Back to top      

  Special Features


Configuration utility automatically finds NetCAN devices in the network

Operating Mode

Automatic Mode switching between Driver and TCP Raw Server Mode.


Over Driver Panels, NetCOM Manager, WEB Browser, serial Console, Telnet, SNMP


special VScom MIB included


Domain Name Server support


special precautions for Firewall environments in Driver Mode


Firmware update over WEB Browser, Telnet

>Back to top      


Password access

Every capabilities of configuration use the same password including SNMP V3

Secure communication

OpenVPN tunnel provides security on WLAN and Ethernet. The tunnel protects the configuration as well as all serial data. It is also usable across the Internet. Strong encryption by SSL-AES up to 256 bit keys

>Back to top      

  Driver and Software


  • Unified VSCAN API for simple access on all Vscom CAN products.
  • Supports Windows, CE, Linux (x86, x86-64, ARM) targets.
  • Supports C/C++, C#, VB.NET, Delphi and LabVIEW.


Mapper DLLs can simulate software interfaces of CAN adapters from other manufacturers.


CANopen examples showing Master/Slave communication


CAN Speed selectable up to 1 Mbit/s


ASCII coding mode

CAN Modes

Standard Mode
Normal operation on CAN bus
Listen Mode
Passive receive of CAN Frames, neither ACK bits nor Error Frames are sent
Self Reception (Echo Mode)
For testing: Transmitted Frames are also received by the adapter

Monitoring Tools

  • NetCAN+ and VSCAN API are supported by Bosch BUSMASTER
  • NetCAN+ is supported by CANHacker via Driver Mode

>Back to top      

  Power and Environment


3-pin Terminal Block with Protective Earth

Power requirements

9 - 54V DC, 0.3A @ 12V, 4W


115×73×25 mm³ (W×L×H)

Operating Temp

−20°C - 65°C

Storage Temp

−20°C 85°C


SECC sheet metal (1mm)




  • DIN-Rail (optional)
  • Wallmount (optional)

>Back to top      

  Ordering Information


NetCAN Plus 110

>Back to top      



WLAN Kit internal
internal module 802.11b/g/n, pigtail and antenna
Purchase time option, not for later retrofitting


WLAN Kit external
USB stick 802.11b/g/n, antenna


Power supply adapter 12V DC, 1A; with Terminal block


DIN-Rail mounting kit


Wallmount kit

>Back to top      


Packing list

  • NetCAN Plus 110
  • CD-ROM with Driver and configuration software

>Back to top      

All the trademarks and brands are property of their rightful owners.