Today:
Search Product:
Select product by model name:

>visionsystems.de/ModGate 813RM (6702.html)
 

Features

  • Controls 8 Modbus lines located virtually anywhere via Ethernet or Internet
  • LAN interface 10BaseT/100BaseTx Ethernet
  • Configuration over WEB Browser
  • Supports Modbus Master Multiplexing
  • Supports TCP/IP, DHCP, ICMP, HTTP, DNS
  • Supports ART (Automatic Receive Transmit control)
  • RS232/422/485 interface selectable by Software
 

 
 

ModGate 813RM

Quick Link: | Features | More Pictures | Overview | Application | Hardware | Interface | Performance | Operating Modes | Power and Environment | Special Features | Security | Ordering Information | Optional Accessories | Download |

|

  More Pictures

Klick on the thumbnails to enlarge them …

>Back to top      

  Overview

Modgate 813RM is an industrial-strength Modbus-Network gateway for connecting four Modbus lines to a network running TCP/IP. It operates without platform and distance limitation.
ModGate 813RM uses Modbus/TCP for communication on the network. The serial ports are configured for Modbus/ASCII or Modbus/RTU, while the serial lines are physically set for RS232, RS422 or RS485. The messages received on the network are sent to the serial lines, messages from the serial ports are sent via network.
Modbus Master Multiplexing is implemented as an extension to the standard. Slaves on serial lines may answer requests from multiple masters. The masters connect to ModGate 813RM by Modbus/TCP or from other serial lines.
The configuration of ModGate 813RM is done via HTTP. The user interface is based on Web 2.0 to provide an easy handling of the options. Besides typical serial parameters the configuration includes RS232/485 for serial physical parameters. Further a Modbus address mapping table is available, defining a target port for a certain Modbus address.
ModGate devices are available with 1 up to 8 serial ports, optional also with WLAN plus Ethernet.

Read the News Article…

  Application

Industrial / Factory / Laboratory automation
Automatic warehouse control system
Wafer fabrication system
SCADA system
Building automation system

  Hardware

Processor

ARM 9 166 MHz

I/O controller

16C950 or compatible

Memory

16MB SDRAM, 2 MB Flash

Connector type

DSUB 9 male for serial Port
RJ45 for Ethernet

>Back to top      

  Interface

Ethernet interface

Auto-detecting 10BaseT/100BaseTx

Protocols

TCP/IP, DHCP, ICMP, HTTP, DNS

Serial interface

RS232/422/485 selected by software

No. of port

8, Speed up to 115200 bps

Available Modes

  • RS232 full duplex
  • RS422 full duplex
  • RS485 4 wire, full duplex
  • RS485 2 wire, half duplex, with echo
  • RS485 2 wire, half duplex, without echo

Signals

  • RS232: TxD,RxD, RTS,CTS, DTR,DSR, DCD, RI, GND
  • RS422: Tx+/-, Rx+/-, GND
  • RS485 2 wire: Data+/-, GND
  • RS485 4 wire: Tx+/-, Rx+/-, GND

RS485 Data control

Controlled by ART (Automatic Receive Transmit control)

>Back to top      

  Performance

Speed

Up to 115200 bps

Parity

None, even, odd

Data bits

7, 8

Stop bits

1, 2

IRQ

None

I/O address

None

>Back to top      

  Operating Modes

Modbus RTU/ASCII

Modbus RTU or Modbus ASCII protocol selected for each serial port individually

DirectMappingMode

Direct mapping of Modbus addresses to serial ports or TCP connections

PromiscousMode

Mapping of serial ports to TCP connections

>Back to top      

  Power and Environment

Power requirements

100 - 240V AC 47-63 Hz, 25VA

Dimension

258×149×45 mm³ (W×L×H)
278×155×46 mm³ with DB9 connectors and DIN rail mounting kit
19" 1HU Rackmount

Operating Temp

0°C - 55°C

Storage Temp

−20°C – 85°C

Case

SECC sheet metal (1mm)

Weight

1.9kg

>Back to top      

  Special Features

Installation

Dip switches set a defined temporary IP Address to contact via WEB Browser

Operating mode

Promiscous Mode
Messages received from the network are sent to the serial port, messages from the serial port are sent to the connected network host.
Mapped Mode
Received messages are scanned for their target address. This address is found in a table, the message is sent to the defined connection (serial or TCP).

Modbus Master Multiplexing

An extension to the standard. Slaves on serial lines may answer requests from multiple masters. The masters connect to ModGate 813RM by Modbus/TCP or from other serial lines.

Configuration

Configuration over WEB Browser

ART

Automatic Receive Transmit control for RS485

DNS

Domain Name Server support

Serial Interface

Serial Interface configurable by software

Firmware

Firmware update over WEB Browser

LEDs

LEDs for Power, serial Tx, Rx, Ethernet Link, Speed

>Back to top      

  Security

Password access

Webinterface is password protected. The password can be changed in the Webinterface.

>Back to top      

  Ordering Information

Art.No

6702

Product Name

ModGate 813RM

Packing list

ModGate 813RM
Power cord
19" mounting kit
CD-ROM with Driver and configuration software
Printed Quick Installation Guide

>Back to top      

  Optional Accessories

DK 35A

DIN-Rail mounting kit

>Back to top      

Download

 
 (Firmware 1.2.3 (Feb 15 2011))
>Back to top      

All the trademarks and brands are property of their rightful owners.
Copyright©2005-2010, VS Vision Systems GmbH. All Rights Reserved.